Skip to main content
Samples available UK-wide delivery

Your Cart

0

Your cart is empty

Start with a sample: real cuts of our floors at £1.99 each, sent to your door across the UK.

Subtotal £0.00
Shipping & discounts calculated at checkout
SSL encrypted, safe and secure
LVT Installation Guide
Fitting guide 8 min read

LVT Installation Guide

Fitting luxury vinyl tile. Where it works, why the subfloor matters more than people expect, and the difference between glue down and click systems.

Start reading
On this page
  1. Where LVT is the right answer
  2. The subfloor decides the result
  3. Glue down or click
  4. Laying out the room
  5. Looking after it
  6. What the published guidance says
  7. Questions about fitting LVT
01

Where LVT is the right answer

LVT is a printed and textured vinyl plank or tile over a rigid or flexible core. It handles water, it is warm underfoot, and it takes traffic well, which is why it ends up in kitchens, utility rooms, bathrooms and hallways where a wood floor would be a compromise.

It is also listed as compatible with underfloor heating, like every engineered wood, laminate and tile floor we supply. Solid wood is the exception: none of the solid floors is listed for it.

Good to know: LVT is thin. Unlike a thick engineered board it does not bridge anything, so every imperfection in the subfloor eventually shows through the surface.
See also
02

The subfloor decides the result

This is the part that catches people out. With a wood floor a slightly imperfect subfloor is forgiving. With LVT it is not, because the plank simply follows whatever is underneath it.

A trowel ridge, a screw head standing proud, a patch of old adhesive, a small hollow: all of them read through a vinyl floor within months, and none of them can be corrected once the floor is down. Preparation is not the boring part of an LVT job. It is the job.

Smooth, not just flat
Run your hand over it. Anything you can feel through a glove you will see through the floor.
Use a levelling compound
Over concrete this is usually quicker and more reliable than trying to grind an existing surface true.
Dry and tested
Water trapped under an impermeable floor has nowhere to go. Test rather than assume.
Clean before you start
A single piece of grit under a plank becomes a permanent bump.
03

Glue down or click

Two constructions share the name LVT, and they are fitted in opposite ways. Glue down LVT, often called dryback, is a plank or tile bonded to the subfloor with adhesive. Click LVT, including the rigid core floors, locks plank to plank and floats.

Every LVT floor in our range is click: 36 rigid vinyl floors, 6.5 mm or 5.2 mm thick, all with the underlay attached. There is no glue down LVT in the range, so the comparison below explains the construction rather than offering a choice between two of our products.

Glue down (dryback)
Bonded to a smoothed subfloor. Amtico, a maker of glue down LVT, says any irregularities in the subfloor will show through the finished floor, and that its adhesive bonded ranges need no expansion gap or silicone sealant at the walls.
Click
The Contract Flooring Association describes click LVT planks that lock together to form a large floating floor, with expansion gaps at the perimeters and around fixed items. The MMFA says floors of this kind should only be laid as a floating installation, with a gap of at least 1.5 mm per running metre on each side of the room as a rule of thumb.
High traffic
The CFA notes that full bonding is sometimes recommended in areas of high traffic, to avoid excessive movement. Whether a particular click floor may be glued is for its manufacturer to say.
Underfloor heating
Both, within the vinyl limit: BEAMA notes that most vinyls should not be heated to above 26 °C. All 36 rigid vinyl floors in our range are listed as compatible.
Bathrooms
All 36 are listed as waterproof, plank by plank. The MMFA says a floating click floor is generally not suited to a wet room with a floor drain, asks for the maker's approval in bathrooms, and says to avoid ponding in any case.
Pro tip: Let the planks reach room temperature before fitting. Vinyl expands and contracts with heat, and a floor laid cold will move once the room warms up.
04

Laying out the room

The same rules as a wood floor, with one addition that is specific to vinyl.

1
Plan the last row before the first
Work out the final width now and adjust the starting row so you never finish on a sliver.
2
Mix from several packs
LVT is printed from a limited number of designs. Working from several packs stops the same grain pattern repeating in a visible rhythm.
3
Stagger the joints properly
Keep end joints well clear of the row alongside. A regular pattern looks manufactured rather than natural.
4
Leave the expansion gap on click floors
Cover it with skirting or beading afterwards. A floating floor pinned at the edges will buckle.
05

Looking after it

LVT is the most forgiving floor we sell, which is exactly why it tends to get neglected.

Sweep more than you mop
Grit is abrasive and the wear layer is what protects the printed design.
Felt pads and wide castors
Narrow hard castors under an office chair will mark a vinyl floor.
Mind strong sunlight
A rug left in one place through a bright summer can leave a visible line.
Mats at external doors
The cheapest maintenance there is, and the most effective.
06

What the published guidance says

Published standards

Each entry is quoted from its source and linked to it. The full set is in the standards reference.

1 of 8
Contract Flooring Association

Click LVT: a floating floor with expansion gaps

The Contract Flooring Association says click LVT planks lock together to form a large floating floor, so correct expansion gaps are needed at the perimeters and around fixed items, and that in areas of high traffic full bonding is sometimes recommended to avoid excessive movement.

The exact wording

“The planks lock together to form a large floating floor, therefore correct expansion gaps should be left at perimeters and around all fixed items to allow movement especially in areas of temperature change. In areas of high traffic sometimes full bonding is sometimes recommended to avoid excessive movements and resulting faults.”

Source: CFA Guide to Contract Flooring - Contract Flooring Association (8th edition, correct as of 17 June 2022), section "Resilient flooring", click LVT
Multilayer Modular Flooring Association

Multilayer modular floors: floating, with a gap per metre

1.5 mm Expansion gap per running metre of floor, each side (rule of thumb)

The MMFA, the European association for multilayer modular floor coverings, says these floors expand and contract with temperature and humidity and should therefore only be laid as a floating installation, with an expansion gap of at least 1.5 mm per running metre of floor on each side of the room as a rule of thumb.

The exact wording

“As MMF floor coverings expand and contract due to changes in ambient temperature or humidity conditions, the flooring should only be laid as a floating installation. … As a rule of thumb: create an expansion gap of min. 1.5 mm per running meter of flooring on each side of the room (e.g. room width 5 m = 8 mm border joint on each side).”

Source: TB 2 - MMFA Technical bulletin 12/2023 - Installation of Multilayer Modular Floor Coverings (English Edition 12/2023), Multilayer Modular Flooring Association
Amtico

Glue-down LVT: a smooth base and no expansion gap

Amtico, a maker of LVT, says for its adhesive-bonded ranges that any irregularities in the subfloor will show through the finished floor, and that no expansion gap or silicone sealant is needed.

The exact wording

“Any irregularities in the subfloor will show through the finished floor. … with all our adhesive bonded ranges an expansion gap or silicone sealant is not needed.”

Source: Amtico LVT Installation Guidelines DES-IN-20250218-08-EN (Signature, Signature Safety, Form, Spacia, Spacia Safety and First)
Contract Flooring Association

Subfloor irregularities telegraph through a thin floor

The Contract Flooring Association says irregularities in a subfloor telegraph through to the surface of a floor covering laid over it, giving fully bonded thin vinyl on a particleboard subfloor as an example, which is why an underlay is used to smooth them out first.

The exact wording

“The purpose of an underlay is to smooth out any irregularities of a subfloor before laying a floor covering which will telegraph these imperfections through to the floor surface (for example fully bonded thin vinyl on a particleboard subfloor may telegraph the joint lines).”

Source: CFA Guide to Contract Flooring - Contract Flooring Association (8th edition, correct as of 17 June 2022), section on underlays
British Standards (BSI)

BS EN 16511 — modular mechanical locked floor coverings

BS EN 16511:2023 specifies characteristics, requirements and test methods for multilayer mechanically locked modular floor panels with a wear-resistant decorative surface layer, supplied as tiles or planks for floating installation in domestic and commercial use.

The exact wording

“This document specifies the characteristics of multilayer mechanical locked floor covering with a wear-resistant and decorative surface layer supplied in panels (either tile or plank form). The floor panels are considered suitable for domestic and commercial levels of use and designed for floating installation.”

Source: BS EN 16511:2023 - Modular mechanical locked floor coverings (MMF). Specification, requirements and test method for multilayer modular panels for floating installation
BEAMA

Vinyl over underfloor heating: 26 °C

26 °C maximum temperature for most vinyls

BEAMA advises that most vinyls should not be heated above 26 °C, so the floor temperature should be restricted, and warns that in rooms with high heat losses such as conservatories a restricted floor temperature may not heat the room sufficiently.

The exact wording

“However, as most vinyls should not be heated to above 26°C, the floor temperature should be restricted. Care should be taken in the design of systems in rooms with high heat losses, such as conservatories, as it may not be possible to sufficiently heat the room with a restricted floor temperature limit.”

Source: BEAMA Underfloor Heating — Choosing your floor covering to maximise your underfloor heating efficiency (April 2020)
Multilayer Modular Flooring Association

Room conditions at the time of fitting

at least 48 h acclimatisation before installation
15-25 °C storage and acclimatisation temperature
35-65 % storage and acclimatisation relative humidity

The MMFA, the European association for multilayer modular floor coverings, requires the flooring to acclimatise for at least 48 hours in the same conditions as the installation area, stored flat and cross-stacked in unopened boxes at roughly 15-25 degrees Celsius and 35 to 65 per cent relative humidity.

The exact wording

“Leave the floor covering to acclimatise in the same environmental conditions as the installation area for a period of at least 48 hours prior to installation. Always store the boards flat and cross-stacked, in their original unopened boxes and at approx. 15-25 °C and between 35 % and maximum 65 % relative humidity.”

Source: Prior to installation — MMFA (Multilayer Modular Flooring Association)
Multilayer Modular Flooring Association

Cleaning — the manufacturers’ own guidance

For multilayer modular floor coverings the MMFA requires low-moisture cleaning methods and states that pooling of liquid on the floor must be avoided under all circumstances.

The exact wording

“Absolutely avoid ponding in any case!”

Source: Basic cleaning — MMFA (Multilayer Modular Flooring Association)
See also
07

Questions about fitting LVT

Do I need to level the floor before laying LVT?
Almost always over an existing concrete floor, yes. Vinyl follows whatever is underneath it, so a trowel ridge, a screw head or a patch of old adhesive shows through the finished surface. A levelling compound over concrete is usually quicker and more reliable than grinding the surface true.
Click or glue down: which should I choose?
Glue down LVT is bonded to a smoothed subfloor, needs no expansion gap and shows any irregularity underneath it. Click LVT floats over an underlay with an expansion gap at every wall, and can be lifted later. The CFA notes that full bonding is sometimes recommended where traffic is heavy. Every LVT floor in our range is click.
Can LVT go over underfloor heating?
Yes, every rigid vinyl plank in our range is listed for it. Keep the floor plus underlay within the thermal resistance the system was designed for, normally 0.15 m²K/W, and run the heating through its commissioning cycle before the floor goes down.
How long does LVT need to acclimatise?
At least 48 hours in the room, flat and cross stacked in unopened boxes at the room's in service temperature, on the MMFA's guidance for multilayer modular floors. Fitting cold boards into a warm room is how a click floor ends up tight at the walls.
Your next step
Find the right LVT for your room
Kitchens, bathrooms and busy hallways are where LVT earns its place. Order a sample and check the texture in the room it is going into.
  • Samples £1.99 each
  • UK-wide delivery
  • Advice before you order
Not sure it suits your room?
A real cut from a real board. Samples £1.99 each, up to 10 per order.
Order samples · £1.99

Join the Homes & Floors Club

New ranges and offers. Hear it first.

  • Room ideas & honest guides
  • New floors first
  • Special offers

No spam. Unsubscribe any time.