Each entry is quoted from its source and linked to it. The full set is in the standards reference.
The expansion gap
The EPLF, the European association of laminate flooring producers, recommends an edge gap of 8 mm to 12 mm on all sides of a floating floor, so that the covering can expand and contract without lifting.
| recommended edge gap on all sides | 8 to 12 mm |
|---|
“To accommodate such changes, a edge spacing should be observed on all sides. A free space of 8 mm to 12 mm is recommended.”
Source: EPLF Technical Bulletin — Installation of Laminate Floor Coverings (06/2022), 6.4 Edge gapsExpansion profiles: doorways and long runs
The EPLF says there should be no physical contact between a finished laminate floor and vertical structures, and that expansion joint profiles belong in doorways between rooms and on floors longer than 12 m along the planks or wider than 8 m across them, with the product instructions deciding.
| Floor length along the planks above which an expansion profile is needed | 12 m |
|---|
| Floor width across the installation direction above which an expansion profile is needed | 8 m |
|---|
“There should be no physical edge contact between the finished floor and vertical solid structures. … Expansion joint profiles should be installed as follows in consideration of the size and geometry of the floor surface: … On surfaces greater than 12 m in the direction of the length of the individual laminate floor covering planks … On surfaces greater than 8 m in the direction of installation travel In doorways between rooms … Manufacturers recommendations regarding maximum uninterrupted flooring sizes vary greatly.”
Source: EPLF Technical Bulletin - Installation of Laminate Floor Coverings (English edition 06/2022), European Producers of Laminate Flooring, 6.4 Edge gaps and 6.5 Expansion joint profilesMultilayer modular floors: floating, with a gap per metre
The MMFA, the European association for multilayer modular floor coverings, says these floors expand and contract with temperature and humidity and should therefore only be laid as a floating installation, with an expansion gap of at least 1.5 mm per running metre of floor on each side of the room as a rule of thumb.
| Expansion gap per running metre of floor, each side (rule of thumb) | 1.5 mm |
|---|
“As MMF floor coverings expand and contract due to changes in ambient temperature or humidity conditions, the flooring should only be laid as a floating installation. … As a rule of thumb: create an expansion gap of min. 1.5 mm per running meter of flooring on each side of the room (e.g. room width 5 m = 8 mm border joint on each side).”
Source: TB 2 - MMFA Technical bulletin 12/2023 - Installation of Multilayer Modular Floor Coverings (English Edition 12/2023), Multilayer Modular Flooring AssociationProfiles in doorways and where floors meet
The MMFA says expansion gap profiles generally belong in doorways between rooms, that the perimeter expansion gaps can be covered with skirting, and that suitable expansion mouldings with sufficient clearance are installed where different floor coverings meet.
“Expansion gap profiles should generally be installed as follows: In doorways between rooms. … The expansion gaps required can easily be covered with corresponding plinths. … In doorways, for room dividing expansion joints and transition areas where different floor coverings meet, suitable expansion mouldings with sufficient clearance should be installed.”
Source: TB 2 - MMFA Technical bulletin 12/2023 - Installation of Multilayer Modular Floor Coverings (English Edition 12/2023), Multilayer Modular Flooring AssociationExpansion space for a floating wood floor
The US National Wood Flooring Association says that, unless the manufacturer directs otherwise, the expansion space between a floating wood floor and vertical obstructions is generally equal to the thickness of the flooring, that transition pieces allowing for expansion belong in narrow doorways, and that trim is held off the floor and never fastened to or through it.
“Unless otherwise directed by the flooring manufacturer, expansion space left between the flooring and vertical obstructions are generally equal to the thickness of the material being installed. … Transition pieces allowing for expansion space should be built into the floating-floor system at any doorways less than 4 feet in width … Trim pieces should be held off of the floor a minimum of 1/16”, and should never be fastened to or through the flooring system.”
Source: NWFA Wood Flooring Installation Guidelines, Revised 2025 - National Wood Flooring Association, floating floors chapterSkirting over the gap, and ramped transitions
The Contract Flooring Association says skirting can conceal the expansion gap at the perimeter, that timber skirting is fixed only to the wall so that it does not restrict the floor, and that a junction between floor coverings of different height may need a slightly ramped transition.
“the skirting can be used to conceal the expansion gap at the floor perimeter. … Timber skirtings should only be fixed to the wall, so as not to restrict any expansion of the floor finish. … For a junction between floor coverings of different height, a slightly ramped transition may be needed.”
Source: CFA Guide to Contract Flooring - Contract Flooring Association (8th edition, correct as of 17 June 2022), sections on skirtings and junctionsSwelling, shrinking and gaps in flooring
The Wood Handbook of the US Forest Products Laboratory says that below fibre saturation wood swells as it gains moisture and shrinks as it loses it, that this can cause warping, checking and splitting and, among other problems, gaps in flooring, and that wood moves most in the direction of the growth rings, about half as much across them and only slightly along the grain.
“Below MCfs, wood changes dimension as it gains moisture (swells) or loses moisture (shrinks) because the volume of the cell wall depends on the amount of bound water. This shrinking and swelling can result in warping, checking, and splitting of the wood, which in turn can lead to decreased utility of wood products, such as loosening of tool handles, gaps in flooring, or other performance problems. … It shrinks (swells) most in the direction of the annual growth rings (tangentially), about half as much across the rings (radially), and only slightly along the grain (longitudinally).”
Source: Wood Handbook — Wood as an Engineering Material, General Technical Report FPL-GTR-282 (2021), chapter 4 "Moisture Relations and Physical Properties of Wood", section "Dimensional Stability", page 4–7 — USDA Forest Service, Forest Products Laboratory