Each entry is quoted from its source and linked to it. The full set is in the standards reference.
Expansion profiles: doorways and long runs
The EPLF says there should be no physical contact between a finished laminate floor and vertical structures, and that expansion joint profiles belong in doorways between rooms and on floors longer than 12 m along the planks or wider than 8 m across them, with the product instructions deciding.
| Floor length along the planks above which an expansion profile is needed | 12 m |
|---|
| Floor width across the installation direction above which an expansion profile is needed | 8 m |
|---|
“There should be no physical edge contact between the finished floor and vertical solid structures. … Expansion joint profiles should be installed as follows in consideration of the size and geometry of the floor surface: … On surfaces greater than 12 m in the direction of the length of the individual laminate floor covering planks … On surfaces greater than 8 m in the direction of installation travel In doorways between rooms … Manufacturers recommendations regarding maximum uninterrupted flooring sizes vary greatly.”
Source: EPLF Technical Bulletin - Installation of Laminate Floor Coverings (English edition 06/2022), European Producers of Laminate Flooring, 6.4 Edge gaps and 6.5 Expansion joint profilesProfiles in doorways and where floors meet
The MMFA says expansion gap profiles generally belong in doorways between rooms, that the perimeter expansion gaps can be covered with skirting, and that suitable expansion mouldings with sufficient clearance are installed where different floor coverings meet.
“Expansion gap profiles should generally be installed as follows: In doorways between rooms. … The expansion gaps required can easily be covered with corresponding plinths. … In doorways, for room dividing expansion joints and transition areas where different floor coverings meet, suitable expansion mouldings with sufficient clearance should be installed.”
Source: TB 2 - MMFA Technical bulletin 12/2023 - Installation of Multilayer Modular Floor Coverings (English Edition 12/2023), Multilayer Modular Flooring AssociationReducer, T-moulding, threshold: what each joins
The US National Wood Flooring Association describes reducers as a smooth transition between floors of uneven heights, T-mouldings as the join between two floors of the same thickness or between floating wood floors in two rooms and in doorways, and thresholds as the transition between floors of different heights at doorways; a T-moulding is attached only to the subfloor, never fastened to the wood flooring, to keep the expansion space.
“Reducers are used to provide a smooth transition between floors of uneven heights. Reducers are often used between wood floors and thinner floor coverings such as vinyl or low pile carpet. … T-mouldings are commonly used to join two areas of flooring that are the same thickness or to join floating hardwood floors between two rooms, in doorways, or where the flooring manufacturer requires additional expansion space based on the floor span. … T-moulding should never be fastened to the wood flooring. It must only be attached to the subfloor, in order to maintain adequate expansion space. … Thresholds are designed for the transition between floors of different heights, and are commonly used to make the transition at doorways, between interior rooms, and to the outside.”
Source: NWFA Wood Flooring Installation Guidelines, Revised 2025 - National Wood Flooring Association, mouldings and transitionsExpansion space for a floating wood floor
The US National Wood Flooring Association says that, unless the manufacturer directs otherwise, the expansion space between a floating wood floor and vertical obstructions is generally equal to the thickness of the flooring, that transition pieces allowing for expansion belong in narrow doorways, and that trim is held off the floor and never fastened to or through it.
“Unless otherwise directed by the flooring manufacturer, expansion space left between the flooring and vertical obstructions are generally equal to the thickness of the material being installed. … Transition pieces allowing for expansion space should be built into the floating-floor system at any doorways less than 4 feet in width … Trim pieces should be held off of the floor a minimum of 1/16”, and should never be fastened to or through the flooring system.”
Source: NWFA Wood Flooring Installation Guidelines, Revised 2025 - National Wood Flooring Association, floating floors chapterSkirting over the gap, and ramped transitions
The Contract Flooring Association says skirting can conceal the expansion gap at the perimeter, that timber skirting is fixed only to the wall so that it does not restrict the floor, and that a junction between floor coverings of different height may need a slightly ramped transition.
“the skirting can be used to conceal the expansion gap at the floor perimeter. … Timber skirtings should only be fixed to the wall, so as not to restrict any expansion of the floor finish. … For a junction between floor coverings of different height, a slightly ramped transition may be needed.”
Source: CFA Guide to Contract Flooring - Contract Flooring Association (8th edition, correct as of 17 June 2022), sections on skirtings and junctionsAccessible threshold: level, or no more than 15 mm
Approved Document M, volume 1 (dwellings), defines an accessible threshold as one that is level or, if raised, has a total height of not more than 15 mm, with as few upstands and slopes as possible and any upstand higher than 5 mm chamfered.
| Accessible threshold, maximum total height | 15 mm |
|---|
“A threshold that is level or, if raised, has a total height of not more than 15mm, a minimum number of upstands and slopes and with any upstands higher than 5mm chamfered.”
Source: Approved Document M - Access to and use of buildings, Volume 1: Dwellings, 2015 edition incorporating 2016 amendments (HM Government), Appendix A key termsThe expansion gap
The EPLF, the European association of laminate flooring producers, recommends an edge gap of 8 mm to 12 mm on all sides of a floating floor, so that the covering can expand and contract without lifting.
| recommended edge gap on all sides | 8 to 12 mm |
|---|
“To accommodate such changes, a edge spacing should be observed on all sides. A free space of 8 mm to 12 mm is recommended.”
Source: EPLF Technical Bulletin — Installation of Laminate Floor Coverings (06/2022), 6.4 Edge gaps